Hotline: 028 3863 5373 - info@citytech.vn
VA-P8500S of 2RU case, with built-in 500W digital amplifier and 8 independent power zones, which can be installed in the broadcasting room or remote control room, share the network audio source with the system via the internet (Includes the EVAC message and network back ground music), support 4 local line inputs (The priority can be set from the main controller), is the ideal unit for setting up medium or small applications.
Features
Support the speaker loop ground connection, open circuit and short circuit test detection.
Support the speaker loop cabling of 3 wire or 4 wire.
8 Programmable online input trigger interfaces
8 Programmable online output trigger interfaces
Support power saving mode when no signal input.
Support the line redundant wiring
Support linkage fire alarm controller and realize fire alarm linkage control
Basic Functions
* With built-in 500W digital amplifier and 8 outputs, LED indicator for each zone, independent output control button and volume control.
* Network EVAC input and BGM input, local emergency mic input, business mic input and 2 line inputs; User can set the priority of the mic in VA-6000ST.
* Can work with 1 extra standby amplifier, when the built-in amplifier come out fautly, the standby amplifier take over automatically.
* Automatically detection on the speaker loop (Ground connection, open circuit, short circuit).
* 8-CH dry and wet input interfaces, can trigger the pre-set voice messages distributed to different zones.
* 8 programmable relay signals output port, can output short circuit voltage control signal to a third party device to realize online automatic control.
* Support 24V DC input interface (To connect the 24V DC supplied by VA-6000BC).
Model |
VA-P8500S |
AC power |
|
Voltage |
~ 230V, 50/60Hz |
Mimum current |
3A (Exclude the 4 wire override output) |
Fuse Data |
250V/5A, Slow type |
DC Power |
DC Power |
Voltage |
24V DC, ¡À20% |
Mimum current |
25A (Exclude the 4 wire override output) |
Power consumation |
600W |
Performance Index |
|
Line input |
|
Distortion |
<1% (RMS), 1kHz |
Frequency |
80Hz~20kHz |
Sensitivity |
350mV |
Impedance |
10k¦¸ |
S/N Ratio |
>70dB |
Emergency Mic |
|
Sensitivity |
5mV |
Impedance |
600¦¸ |
Contactor Output |
|
8-CH programmable relay output |
Short Circuit, No voltage |
8-CH programmable trigger input |
8-CH programmable trigger input |
Level mode |
Max 3.3V |
Short circuit mode |
No voltage, Short circuit. |
Cooling mode |
Air-Cooled |
Protection mode |
Delay/Overheat/Short Circuit/Over Load |
Machine Index |
|
Dimension |
484 x 88 x 447 mm (19' width, 2U) |
N.W |
About 11.kg |
Installation |
Desktop or 19 inch cabinet |
Color |
BLACK |
Enviroment Requirements |
|
Operation Temp |
+5¡æ ~ +40¡æ |
Storage Temp |
-20¡æ ~ +70¡æ |
Relative Temp |
<95% (No condensation) |